| Sign In | Join Free | My rc363.com |
|
Brand Name : G-Tech
Model Number : 1 kVA ~ 10 kVA (3:1)
Certification : CE ROHS
Place of Origin : Guangdong, China
MOQ : 50pcs
Payment Terms : L/C, T/T, Western Union
Supply Ability : 10000pcs
Delivery Time : 7-25workdays
Packaging Details : Carton packing
Price : Negotiation
Protection : Unbalanced Loads
Transfer time : 0ms
Power factor : 6k and 10k with power factor is 1.0
Crest factor : 3:1
Specifications
| MODEL | PT-1K | PK-1KL | PT-2K | PT-2KL | PT-3K | PT-3KL |
| Capacity | 1000VA/9000W | 2000VA/1800W | 3000VA/2700W | |||
| INPUT | ||||||
| Voltage range | Full load:160Vac ±5%-300Vac±5%; no-load:110Vac±-300Vac±5% | |||||
| Power factor | 0.9 | |||||
| Frequency range | 40Hz-70Hz | |||||
| Phase | Single phase with ground | |||||
| OUTPUT | ||||||
| Output voltage | 220Vac | |||||
| AC Voltage regulation | ±1% (Batt.Mode) | |||||
| Frequency range | 47-53Hz of 57-63Hz(Synchronized range) | |||||
| Frequency range | 50±0.25Hz or 60±0.3Hz(Batt.mode | |||||
| Overload | >100%<110%:warning >110%<130%:UPS shuts down after 1 minute in battery mode,or transfer to by pass when the utility is normal >130%:UPS shuts down immediately in battery mode,or transfer to bypass when the utility is normal. | |||||
| Current crest ratio | 3:1 | |||||
| Harmonic distortion | ≤6% THD(non-linear load) | |||||
| Transfer time | AC Mode to Batt Mode:0ms; Inverter to Bypass:4ms(Typical) | |||||
| Wave form(Batt.Mode) | Pure Sinewave | |||||
| EFFICIENCY | ||||||
| AC Mode | ≥85% | ≥88% | ||||
| Battery Mode | ≥83% | ≥85% | ||||
| Battery | ||||||
| Battery type (standard Mode) | 12V/7-9AH | |||||
| Quantity | 2pcs | 6pcs | 6pcs | 8pcs | ||
| Recharging time | 4 hours recover to 90% capacity(Typical) | |||||
| Charging current | Standard Model :1A(max) | |||||
| Charging voltage | 27.3V±2%/41.0V±2% | 55.2V±2%/82.1V±2% | 82.1V±2%/109.4V±2% | |||
| PHYSICAL | ||||||
| Dimension(mm) | 350*145*230 | 410*190*325 | ||||
| Net weight(kg) | 18.6 | 9.0 | 19.0 | 10.0 | 25.0 | 11.0 |
| ENVIRONMENT | ||||||
| Operation humidity | 20-95%RH@0-40℃(non-condensing) | |||||
| Noise level | ≤40dB(1m) | |||||
| MANAGEMENT | ||||||
| Smart RS232 or USB | Rs232(default) USB(optional) | |||||
| Optional SNMP | Power management from SNMP manager and web browser | |||||
Feature
1,True double-conversion
2,Microprocessor control optimized reliablity
3,Input power factor correction
4,Output power factor is 0.9
5,Wide input voltage (110V-300V)
6,Converter mode available
7,Generator compatible
8,Smart SNMP works well with either USB or RS-232

|
|